歡迎您光臨本站 註冊首頁

service rgmanager start 出錯

←手機掃碼閱讀     火星人 @ 2014-03-04 , reply:0

service rgmanager start 出錯

Hi, All guys;

    配置好cluster.conf之後,運行service cman start 可以順利看見集群建立成功,
接著運行service rgmanager start,也提示OK,但是/var/log/messages提示出錯,as below;
Sep 14 11:14:03 fsommfe02 clurgmgrd: <notice> Resource Group Manager Starting
Sep 14 11:14:03 fsommfe02 clurgmgrd: <warning> Node fsommfe01pri1 has no nodeid attribute
Sep 14 11:14:03 fsommfe02 clurgmgrd: <warning> Node fsommfe02pri1 has no nodeid attribute
這是什麼原因啊,有大佬碰到這問題並順利解決的嗎??
以下是我的一些集群信息:
CLUSTER.CONF:
<?xml version="1.0"?>
<cluster config_version="3" name="gtc_test">
        <fence_daemon post_fail_delay="0" post_join_delay="3"/>
        <clusternodes>
                <clusternode name="fsommfe01_pri1" nodeid="1" votes="1">
                        <multicast addr="239.0.0.1" interface="eth2"/>
                        <fence>
                                <method name="1">
                                        <device lanplus="1" name="fence01"/>
                                </method>
                        </fence>
                </clusternode>
                <clusternode name="fsommfe02_pri1" nodeid="2" votes="1">
                        <multicast addr="239.0.0.1" interface="eth2"/>
                        <fence>
                                <method name="1">
                                        <device lanplus="1" name="fence02"/>
                                </method>
                        </fence>
                </clusternode>
        </clusternodes>
        <cman expected_votes="1" two_node="1">
                <multicast addr="239.0.0.1"/>
        </cman>
        <fencedevices>
                <fencedevice agent="fence_ipmilan" auth="password" ipaddr="139.122.10.201" login="fence01" name="fence01" passwd="er
icsson"/>
                <fencedevice agent="fence_ipmilan" auth="password" ipaddr="139.122.10.202" login="fence02" name="fence02" passwd="er
icsson"/>
        </fencedevices>
        <rm>
                <failoverdomains>
                        <failoverdomain name="dccfailover" ordered="0" restricted="1">
                                <failoverdomainnode name="fsommfe01pri1" priority="1"/>
                                <failoverdomainnode name="fsommfe02pri1" priority="1"/>
                        </failoverdomain>
                </failoverdomains>
                <resources>
                        <ip address="139.122.10.208" monitor_link="1"/>
                </resources>
                <service autostart="0" domain="dccfailover" name="dcc" recovery="relocate">
                        <ip ref="139.122.10.208"/>
                </service>
        </rm>
</cluster>


CLUSTER STATUS::
# clustat -l
Cluster Status for gtc_test @ Tue Sep 14 11:55:29 2010
Member Status: Quorate

Member Name                                                     ID   Status
------ ----                                                     ---- ------
fsommfe01_pri1                                                      1 Online, Local, rgmanager
fsommfe02_pri1                                                      2 Online, rgmanager

Service Information
------- -----------

Service Name      : service:dcc
  Current State   : disabled (119)
  Owner           : none
  Last Owner      : none
  Last Transition : Thu Jan  1 08:00:00 1970

# clusvcadm -e dcc -m fsommfe01_pri1
Member fsommfe01_pri1 trying to enable service:dcc...Failure
# clusvcadm -e dcc -m fsommfe02_pri1
Member fsommfe02_pri1 trying to enable service:dcc...Failure

如果大佬們還需要什麼信息,在線等;

THANK YOU IN ADVANCE;

PS:
有知道紅帽的SUPPORT 電話嗎?收費嗎?什麼情況給你提供服務?
BR//GG
《解決方案》

需要購買訂閱,
一個節點一個訂閱
《解決方案》

額,那完蛋了,樓上的兄弟有沒有碰上該問題啊
《解決方案》

本帖最後由 hb_li_520 於 2010-09-14 18:28 編輯

# clusvcadm -d dcc  看一下結果~~~
把服務放在啟動狀態不然返回不是"0"....RHCS也會報錯。
《解決方案》

兩個節點都重啟一下吧。

[火星人 ] service rgmanager start 出錯已經有843次圍觀

http://coctec.com/docs/service/show-post-5448.html